Description

DIN-Rail Mount Dimmer 2ch 6A /per ch. with scene controller (Overheat, Overload, Surge Protection) single phase both 220/110 VAC, 50-60Hz (Green operated supplied by 24VAC/30mA) Small and elegant with easy labeling space, output status LED indicator, network health, broadcast address button and Momentary channel button. Can be used in any location that require energy saving, intelligent control such as apartment, Villa, Offices, Restaurant, Hotels or factories. Can be Manually Programmed by any Electrician on site without need for PC.

Load Compatibility:

• Leading edge electronic transformers (Spot/Down Lights++)
• Incandescent lamps
• Track lighting
Connection Port:


Smart-Bus Dimmer 2ch Connection Port 
TECHNICAL DATA:
Supply
80-240V, 50/60Hz Single Phase
power consumption: 20-30mA
Outputs
2 x dimmed outputs
(leading edge phase control) at
6A each output channel
Maximum Total Load
10A recommended total load
Control IO
3 x Advanced RS485 S-BUS
serial port links (both train &
screw link types)
Upgrade IO
1 x mini USB port (to connect to
special programming board)
User Controls
• front panel override switches,
Includes ON/OFF/AUTO override
switch for each channel
• LED status indicator/channel
• Diagnostic LED+ BROADCAST
Programming
• Manual Ch. Pairing Programming
Each Channel to a Button
on Wall Panels (e.g. DDP, 6B)
• Advanced Software Configuration
& Programming
Compliance
CE Mark Low Voltage
CE Mark EMC
Internal Protection
• Over Heat Protection
• Over Load Protection
• BUS Rv. Polarity Protection
• BUS Short Circuit Protection
Preset and Scenes
2X12 Built in Scenes, and 2X4
Sequence Modes and Logics.
Installation
• 35mm DIN-Rail Mount Ready
• Wall Mount Ready (8P)
SBUS DC Supply
24VDC with flexible tolerance
between 8-32VDC. Flexible
ability to add power supply as
to be needed any where
Supply Terminals
Line, 3X Neutral. 2 x 2.5mm2
or 1 x 4mm2 max conductor size
Output Terminals
COM. 1X OUT for each channel
1 x 4mm2 max conductor size
Operating Environment
-10º to 45ºC ambient temperature
10% to 93% RH
Enclosure & Size
Polycarbonate, DIN-rail (8 Unit)
Dimensions & Weight
W 91mm x L 145mm x H 75mm
Packed weight 0.6kg

Electrical Diagram 


WHY G4 (GENERATION-4) IS BETTER? DIMMER MODULES (2CH, 4CH, 6CH)



Dimmer Control Modules (Features compared)
Old Smart-BUS
New S-BUS G4
Din Rail and Wall Mountable Installation
Only DIN
Both
S-Connector Technology (No Bus Wiring inside DB Train Line)
Not Possible
Available
Easy to See Network Status LED for Health and Problems for dressed DB
Not Possible
Available
Upgrading without opening the Device
Not Possible
By Mini USB
Ability to Snap Connect/Disconnect Cables
Not Possible
Snap In Connector
Ready with up to 12 Channels on single Module
Not Possible
Available
PCB Electronics Design Complexity
Random
Organized
Easy Backup and Restore using Configuration SW
Not Available
Available
Heat Sink, Heat Transfer Surface, Air circulation; and Parts Heat space
Standard
Advanced, Double efficiency
Protection for Cable Harness against Heat Sink
Not Possible
Modified
Updated Channel Operation status on DLP and SW if Manually Changed
Available
Available
Work on Both BUS and Cloud Technology
Not Possible
Possible
Programming and Pairing Manually to DDP, FDP, 6B,4B,3B
Not Possible
Easy
well designed Air cooling Vents at Back and front and Side of Module
Standard
Advanced, Double efficiency
Big Easy Label Space for Installer labeling
Small, Not Easy
Visible and Wide
Colors Distinguisher Face Plates (to know which product is which)
Not Available
Available
Genuine Patent and Brand Embedded into all Parts and Plastics
Not Available
Available
Genuine Product Barcode GTIN, and Holographic Label Distinguisher
Not Available
Available
All Other Standard Smart-BUS Advanced Automation Features
Included
Included
S-bus Connection 



Q. Does dimming affect halogen lamp life?
A. No, not at all. Dimming increases incandescent lamp life. Halogen lamps are incandescent lamps with a tungsten filament. Smart-Bus's pilot test data suggests that halogen lamps will have an expected lamp life similar to other incandescent lamps when dimmed. As an example, 1 type of halogen lamp with a rated life of 2,000 hrs dimmed to 80 V has a life extension of at least 5 times.

Q. Why do dimmers get warm, and is this safe?
A. The technical explanation: During normal operation, solid-state dimmers generate heat. A solid-state dimmer is roughly 98% efficient – 2% of the power is dissipated as heat, which causes the dimmer to feel warm to the touch. The closer a dimmer is run to full output and the higher the load (watts) on the dimmer, the warmer it will feel.
This is perfectly normal and safe. Smart-Bus dimmers are designed to the strictest UL safety standard.

Q. How Much Load can, Din Rail, Dimmer take?
A. Smart-Labs ® has designed the (G4) dimmers to take a Maximum Load of 12Amps, however it is always advisable to de-Rate and calculate maximum load at 10Amps only as per Specification sheet.
Q. What happen if we put big power supply more than 2A/24VDC ( Note: In Clipsal Schneider case, we damage network if we do that.) so will that also similarly damage the dimmers in smart bus case?
A. No, there is no harm at all, the S.BUS is designed with high flexibility and good amount of protection. You can add big power supply as you like, in example 30A/24VDC for even bigger Amp. to one dimmer or relay with only one switch.. the s.bus will still function perfectly. Smart-BUS is designed way differently compared to other manufacturers.

Q. What is the maximum voltage that the smartbus can take before it burns its chip?

A. 45 VDC max

Q. What happen to the bus chip if all the wires of the bus Are shorted?
A. Mostly nothing because s-bus is protected, and once the short circuit issue is resolved then sbus should function normally.

Q. Can we use electric cables instead of data cables to communicate between bus in case we have no data cables?
A. Yes, you can use any conductor cable which is brass, that should work fine.
Q. What fuses are used to protect against overloading inside the Smart-BUS?
A. sBUS uses slow burning fuses to protect the Modules. Usually 4A fuse is used with every channel of 2A, while 6Amp fuse is used with every channel rated 3A, and 10 Amp fuse is used for every channel rated as 6Amp. (in case you overload and burn the fuse, request pro technician to Simply replace it for you)
Q. How long the Smart-BUS wire can be?
A. we tested the BUS as far AS 1200 meters of distance and found operational. (Bigger Conductor is needed for Power in such case)
Q. Does every S-BUS Dimmer have scenes built into the module, or we have to buy scene controller?
A. No need to buy any extra modules, each dimmer has scene controller function built in. Smart-Group always adds all needed features as possible inside same module to help save money, time, space and environment.
Q. what if we have 2 channels installed on the 6A dimmer, but one of them is only 2Amps, while the other one is 7.5Amps, will that burn the dimmer?
A. As long as the total load is below 10Amps collectively, the Dimmer will remain functional. Meaning that 7.5Amp Load can be handled without any issue since the other load is below 2Amp. making both loads total 9.5Amp that is within permissible range.
Q. Do we have to de-rate because of Spark effect when we design electrical digial Relays control panels DRP or Dimmer Panels DDP?
A. No. you do not have to de-rate. We have done this for you already when we have designed the Relays and Dimmers at our R&D labs. (To be on safer side, all you need is to accurately calculate the load based on your country Electrical Voltage and constant fluctuations if any)
Q. How many dimmers can be connected with the Train connecter that is built in the dimmer Module?
A. from experiment, we had no limitation; you can connect as many as you can inside the DP on Single DIN-rail. In case you have multiple Din-Rails, please bridge using side S-BUS Connector.
Q. what happens if communication BUS voltage drops below 24VDC, and what happen if it exceed that? (Question case example: in Dynalite case, the running BUS voltage is 12VDC, but we usually lose data communication if it drops below 10VDC, and network cards burn in case voltage is more than 15VDC)
A. In Smart-BUS case, the recommended working voltage is 24VDC, there is tolerance between 10-32 volts with perfect operation. If voltage drop below 8VDC then communication might be lost, and if voltage exceeds 45VDC then also S-BUS network ports will burn. When we designed the smartHome-BUS, we made it as bullet proof as possible with maximum voltage change flexibility imaginable at any normal case.
Q. What is radio frequency interference (RFI)?
A. RFI is a buzzing noise that may occur in some audio and radio equipment when solid-state dimmers are used nearby. Although every Smart-Bus dimmer contains a filter to suppress RFI, additional filtering may be required in some applications. Typical examples of RFI-sensitive equipment are AM radios, stereo sound systems, broadcasting equipment, intercom systems, public address systems, and wireless telephones.

Q. Doesn't turning the lights on and off so quickly decrease bulb life?
A. No. Switching the bulb does not decrease bulb life; heat decreases bulb life. By reducing heat, bulb life is increased.
Referrence websites:
Http://www.smarthomebus.com (Home Automation Control DRP System)
Http://www.sunseeker.me (Motorized Shades, Drapes & Lifts)
Http://www.zone-audio.com (Multi-room Distributed Audio System)
Http://www.resound.me (Theatre Art Speaker and Garden Hi-end Autosystem)
Http://www.oursmartwall.com (Specialized in Automation and A&V Industry Social Website)
 

Smart-Bus 9 in 1 Multifunction Sensor (G4) - SB-9in1T-CL.GTIN (UPC-EAN): 0610696253996

 

 

 

Description

Bus Enabled, Addressable Ceiling Mountable 9in1 Multi-Functional sensor. One device has 9 functions designed perfectly for Automation Industry techno-lifestyle needs. This All-in-One device contains: (addressable Motion sensor, light intensity LUX sensor, Infrared receiver for easy access by remote control, 360 degrees infrared transmitter to control 250 IR codes of electronic equipment like TV, DVD...etc., addressable 2-Zone Dry contact inputs one is for Safety, and one is for Security to connect to the room window sensor and smoke detector or any other sensor, save the wiring and programming time, it has 32 Logic lines (if, then, and or, nand, nor), and it support Burgular Security Code input checking, arming and disarming, it has Built in Temperature Sensor that can be paired to HVAC2 Module, and for other reading needs)
**Added function: Easy S-BUS Connectors, Temperature Sensor, and mini USB firmware upgrade port, & Advanced mechanical design and size to fit ceiling boxes twist in.

Control Compatibility:

• Security
• Safety
• Maintenance
• Health
• Automation
• HVAC

TECHNICAL DATA:

Inputs
2-Dry Inputs (Volt Free) +
1 PIR 10mX110 degrees ,
1 LUX Sensor Inbuilt,
IR Receiver inbuilt,
1 Temperature sensor inbuilt.

NO/NC
Internal Assignment enabled
Applications
• Security Applications in connection
to: (vibration, UV, magnetic
contacts, Panic, Pressure
matt, PIR, microwave, Driveway
sensors...etc.)
• Safety Applications in connection
to: (Gas Leak, Smoke,
Pool Guard, Elevator Panic, CO
gas, Bathroom Help..etc.)
• Maintenance and Health Applications
in connection to: (water
Leak detector, water tank low
level alert, Filter sensor...etc.)
• Logic Control
• HVAC and energy Saving
User Controls
• LED status indicator/channel
• Diagnostic LED+ BROADCAST
Programming
• Advanced Software Configuration
& Programming
• Manual pairing to HVAC and 1
Light channel with default 10
Min, timer
Compliance
CE Mark EMC
Controls
1 x Advanced RS485 S-BUS
serial port links (both train &
screw link types),
1 x 360 degree IR emitter
32 logic lines & 250 prog. Flags
250 IR codes can be saved
Burglar security and Home
safety Zone control function.
Upgrade IO
1 x mini USB port (to connect to
special programming board)
Operation Protection
• BUS Rv. Polarity Protection
• BUS Short Circuit Protection
SBUS DC Supply
24VDC with flexible tolerance
between 8-32VDC. Flexible
ability to add power supply as
to be needed any where
Power consumption: 15mA
Installation
• Ceiling Mount Twist & Lock
Ready
Operating Environment
0º to 45ºC ambient temperature
20% to 93% RH
Enclosure & Size
Polycarbonate
Dimensions & Weight
W 85mm x L 85mm x H 39mm
Packed weight 0.15 kg

WHY G4 (GENERATION-4) IS BETTER? 9IN1 SENSOR, 6IN1, 5IN1


9in1 Sensor, 6in1 Sensor
(Features compared)
Old Smart-BUS
New S-BUS G4
Easy To Open and close without stocking
Difficult
Easy
Easy Twist and Screw Installation Simplicity
Not Available
Available
Ability to Snap Connect/Disconnect Cables
Not Possible
Snap In Connector
Electronic Board can Be easily removed and protected till Installation Time, while base and connectors remain
Not Possible
Possible
Upgrading the Device Made Easy
Difficult
By Mini USB
Temperature Sensor Built in and Can Link to HVAC2
Not Available
Available
Unified Milky White Color that dissolve into ceiling without the Brown IR Emitter ring cover 9Avoided)
Not Available
Available
Advanced cable Run Design to accommodate Finished Installation Needs at Concreted Ceiling Homes
Not Available
Available
Easy Backup and Restore using Configuration SW
Not Available
Available
Work on Both BUS and Cloud Technology
Not Possible
Possible
Advanced Spacing and Isolation to avoid Electromagnetic Field false Signaling
Not Available
Available
well designed Air cooling Vents at base of Module
Standard
Advanced, Double efficiency
Genuine Patent and Brand Embedded into all Parts and Plastics
Not Available
Available
Genuine Product Barcode GTIN, and Holographic Label Distinguisher
Not Available
Available
All Other Standard Smart-BUS Advanced Automation Features
Included
Included
Smart-Bus 9 in 1 Multifunction Sensor (G4) - SB-9in1T-CL - GTIN (UPC-EAN): 0610696253996
Smart-Bus 9 in 1 Multifunction Sensor (G4) - SB-9in1T-CL - GTIN (UPC-EAN): 0610696253996

Q. What is the Range of Motion detection and IR range for every sensor?
A. a motion Detection range of 10 meters diameter (5 in every direction from sensor center) if installed at height of 3m. and IR transmission Range of 12 meter diameter (6 in every direction).
Q. How many programmable logic lines available in every multi-function sensor?
A. there are 32 Logic lines and 250 programmable flags. (Each sensor is considered a complete Zone Automation control commander; it would have been complete system if it has built in Time clock with battery).
Q. which sensors have built-in Temperature couple and what is the use of this?
A. both 9in1 and 6in1 sensors have built-in Thermal couple for temperature reading. It can be used to Pair with HVAC2, or to act as temperature reading source for SW, Touch screen, or DDP. It can also be used to average the temperature of several reading devices or points in the same space. Best application for it is the use in one zone where only one HVAC supply multi areas, in such case if temperature threshold is reached in the slave zone then AC shall trigger regardless if Main DDP desired or current temperature settings are differently assigned. Priority will be given to the critical zone as per logic command.
Q. How many Dry contact inputs the Multi-sensor Have, and can we put more than one door or window magnetic contact on single zone?
A. each Multi-Sensor have 3 addressable zones, Only 2 of which are assigned for dry Inputs. On each addressable dry input, installer can connect on series as many doors or windows needed, but must understand that either one of them is open then, all will be reported unsecure.

Referrence websites:
Http://www.smarthomebus.com (Home Automation Control DRP System)
Http://www.sunseeker.me (Motorized Shades, Drapes & Lifts)
Http://www.zone-audio.com (Multi-room Distributed Audio System)
Http://www.resound.me (Theatre Art Speaker and Garden Hi-end Autosystem)
Http://www.oursmartwall.com (Specialized in Automation and A&V Industry Social Website)

SMART-BUS G4 DYNAMIC DISPLAY PANEL DDP EU WITH LCD - SB-DDP-EU


All in one wall Switch, the DDP is an elegant and easy to use wall panel that eliminates wall agony. It has built in thermostat, changeable labels to identify every button use, can control lights, curtains, temperature, music, and TV. DDP has easy fascia color and material changing flexibility to help match any interiors. The DDP has screw less mounting mechanism, security lock, easy upgrade mini-USB, re-locatable IR receiver probe, LED backlit buttons and LCD screen. DDP can accept Multi languages, Icons and Graphics
**Added function: Bigger buttons, Elegant aluminum surround and buttons, mini USB firmware upgrade port, better Temperature sensor, easy connectors. Security lock screw to prevent vandalism.

Control Compatibility:

• Lighting
• Climate
• Music
• Curtains
• Moods
• Media
• Security
• Service
• Color
• Drapes
• Pumps
• Gates




TECHNICAL DATA:

Screen Pages
Total 13 pages, (4 flexible use)
7P for HVAC (1 Master+6 Slave)
1P for Music
1P for Floor Heating/Cooling
Extra features
Lockable keys/ buttons
Calibrate able temperature +5-
Changeable fascia colors
LED backlit buttons and LCD
Reloadable IR receiver 15m
Screw less mounting
Easy sBUS connector tech.
Control Applications
lighting, HVAC, security, motorized
shades, music, moods
and scenes, fountains, irrigation,
gates, LED color, service
request, panic, code entry,
lifts, media equipment...etc.
User Controls
• user control buttons
• Diagnostics + BROADCAST
Button behavior
Single click (on/Off toggle)
Double click (mood/Macro)
Keep press (dim/ramp)
Programming
• Manual Pairing to Lighting,
HVAC and Audio modules
• Advanced Software Configuration
& Programming
Compliance
CE Mark EMC
Total Gangs
This DDP is equal to 104 gangs
Control IO
1 x Advanced RS485 S-BUS
serial port links (both train &
screw link types)
Upgrade IO
1 x mini USB port (to connect to
special programming board)
Operation Protection
• BUS Rv. Polarity Protection
• BUS Short Circuit Protection
SBUS DC Supply
24VDC with flexible tolerance
between 8-32VDC. Flexible
ability to add power supply as
to be needed any where
Power consumption: 25mA
Installation
• wall Mount metal frame twist
• Magnetic screw less mounting
• Advanced security locking
• Easy sBUS connector tech.
Operating Environment
0º to 45ºC ambient temperature
20% to 93% RH
Enclosure material
Polycarbonate
Dimensions & Weight
W85mm x L85mm x H12mm x
D8mm. Backed weight 0.22 kg

WHY G4 (GENERATION-4) IS BETTER? DDP, FDP, 6B, 4B, 3B



Switches and wall panels (Features compared)
Old Smart-BUS
New S-BUS G4
Buttons and Surround Finish Material Improvement
Plastic
Aluminum
Glass Material Improvement
Thick & Bulky
I Phone Quality 0.8mm Glass
Back Module Size
Do not Fit all Countries
Fits all countries
Upgrading without opening the Device
Not Possible
By Mini USB
Ability to Snap Connect/Disconnect Cables
Not Possible
Snap In Connector
Ability to Locate IR receiver nearer to user location
Not Possible
Flexible with Snap in Connector
PCB Electronics Design Complexity
2 Complex Boards
Single simple Board
User Graphics Interface
Standard
Improved Icons
Integration to Z-Audio with auto update
Manual
Advanced Auto
Fixed Display Panel (FDP)
Not Available
Available
Easy Backup and Restore using Configuration SW
Not Available
Available
Work on Both BUS and Cloud Technology
Not Possible
Possible
Buttons Size and Workability of Soft switches (1-6 Gang)
Smaller, single side operation
Wider and Bigger with Both sides Operation
Panels Security not to be simple to remove from wall
Not Secure
Secured by Clamps, Magnets, and screw Locks
Metal Plate Twist and Screw Installation Simplicity
Not Possible
Possible
Design Standards
Asian Curved Design
Modern European Touch
Anti static Electricity Grounding and discharge
Not Part of Original Design
Embedded and Implemented in Design
Programming and Pairing Manually to Lighting, Dimming, HVAC, and Music
Not Possible
Easy
Flexible Fascia changing (many varieties)
Difficult, Very Thick
Easy
All Other Standard Smart-BUS Advanced Automation Features
Included
Included
Q. If the customer wants to stop the shutter in the middle, how it can be done? Must use logic?
A. If you would like to add the function of stopping shutter, you don't need make the logic. You can do the programming as following:
Make one button on DDP as the function of stopping shutter:
Button Mode: Combination off,
Button configuration: suppose to you are using CH 1 & CH 2 as shutter, make ch1 & Ch2 both off

Q. How to Backup the Device
A. Go to Menu Backup, Device Backup